Power Distribution
Download the full catalog
View Transformers catalog
-
Pole Transformer (Normal & Salinity-Tolerant)
PRODUCTS
APPLICATION
Pole transformer is applied on 22.9kV 3-phase 4 wires
multi-point grounding system with singlephase silicone steel plate metal pinPole transformer is applied on 22.9kV 3-phase 4 wires multi-point grounding system with singlephase silicone steel plate metal pin
CHARACTERISTIC
- Minimized power loss
- High temperature rise limitation (radiator not required)
- Eco-friendly material (plant oil, fire retardant)
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Type Enclosing Box Capacity (kVA) Efficiency (100%) Voltage regulation (%) No-load current (%) No-load loss (W) Load loss (W-100% load) Dimension W / D / H (mm) Weight Normal Steel 30 Min 98.71 Max 1.5 Max 1.0 Max 62 Max 327 480(W)/610(D)/1,160(H) 235 50 Min 98.83 Max 1.4 Max 0.8 Max 89 Max 501 595(W)/660(D)/1,210(H) 310 75 Min 98.92 Max 1.4 Max 0.8 Max 132 Max 681 595(W)/720(D)/1,240(H) 380 100 Min 98.99 Max 1.3 Max 0.7 Max 165 Max 851 645(W)/730(D)/1,260(H) 450 Salinity-tolerant Stainless 30 Min 98.71 Max 1.5 Max 1.0 Max 62 Max 327 480(W)/610(D)/1,160(H) 230 50 Min 98.83 Max 1.4 Max 0.8 Max 89 Max 501 595(W)/660(D)/1,220(H) 305 75 Min 98.92 Max 1.4 Max 0.8 Max 132 Max 681 595(W)/720(D)/1,250(H) 370 100 Min 98.99 Max 1.3 Max 0.7 Max 165 Max 851 645(W)/730(D)/1,270(H) 435 -
Amorphous Transformer (Normal & Salinity-Tolerant)
PRODUCTS
APPLICATION
Amorphous transformer is applied on 22.9kV 3-phase 4 wires multi-point grounding system with
amorphous metal pin. (Less no-load loss)CHARACTERISTIC
- Minimized power loss
- High temperature rise limitation (radiator not required)
- Eco-friendly material (plant oil, fire retardant)
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Type Enclosing Box Capacity (kVA) Efficiency (100%) Voltage regulation (%) No-load current (%) No-load loss (W) Load loss (W-100% load) Dimension W / D / H (mm) Weight Normal Steel 10 Min 98.51 Max 2.0 Max 1.2 10 141 420(W)/550(D)/1,050(H) 142 20 Min 98.78 Max 1.7 Max 1.2 15 230 470(W)/600(D)/1,120(H) 204 30 Min 98.88 Max 1.5 Max 1.0 20 309 490(W)/660(D)/1,200(H) 245 50 Min 99.05 Max 1.4 Max 0.8 27 498 595(W)/660(D)/1,220(H) 330 75 Min 99.05 Max 1.4 Max 0.8 38 678 635(W)/720(D)/1,250(H) 430 100 Min 99.09 Max 1.3 Max 0.7 52 754 645(W)/730(D)/1,360(H) 505 167 Min 99.20 Max 1.3 Max 0.7 59 1,140 820(W)/760(D)/1,280(H) 515 Salinity-tolerant Stainless 10 Min 98.51 Max 2.0 Max 1.2 10 141 420(W)/550(D)/1,050(H) 138 20 Min 98.78 Max 1.7 Max 1.2 15 230 470(W)/600(D)/1,120(H) 198 30 Min 98.88 Max 1.5 Max 1.0 20 309 490(W)/660(D)/1,200(H) 225 50 Min 98.96 Max 1.4 Max 0.8 27 498 595(W)/660(D)/1,220(H) 315 75 Min 99.05 Max 1.4 Max 0.8 38 678 635(W)/720(D)/1,250(H) 420 100 Min 99.20 Max 1.3 Max 0.7 52 754 645(W)/730(D)/1,360(H) 500 167 Min 98.70 Max 1.3 Max 0.7 59 1,140 820(W)/760(D)/1,280(H) 515 -
Pad Mounted Transformer (Compact type)
PRODUCTS
APPLICATION
Pad mounted transformer is applied on underground distribution line. (Urban, industrial area)
CHARACTERISTIC
- Protected power source side
- Electrical safety device applied (protection fuse)
- Compact size and easy installation
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Phase (Φ) Capacity (kVA) Efficiency (100%) Voltage regulation (%) No-load current (%) No-load loss (W) Load loss (W-100% load) Dimension W / D / H (mm) Weight Single
1Φ50 Min 98.60 Max 1.4 Max 0.8 Max 105 Max 590 1,000(W)/1,000(D)/950(H) 620 100 Min 98.90 Max 1.4 Max 0.7 Max 175 Max 920 1,000(W)/1,000(D)/950(H) 800 200 Min 98.90 Max 1.3 Max 0.6 Max 300 Max 1920 1,000(W)/1,400(D)/1,050(H) 1310 Triple
3Φ75 Min 98.50 Max 1.8 Max 1.7 Max 210 Max 930 1,500(W)/1,000(D)/1,150(H) 1310 150 Min 98.60 Max 1.5 Max 1.6 Max 300 Max 1820 1,500(W)/1,100(D)/1,150(H) 1480 300 Min 98.70 Max 1.4 Max 1.0 Max 510 Max 3400 1,500(W)/1,100(D)/1,150(H) 1780 500 Min 98.80 Max 1.3 Max 0.8 Max 750 Max 5320 1,500(W)/1,250(D)/1,150(H) 2300 -
Distribution Transformer
PRODUCTS
APPLICATION
Distribution transformer is insulating oil cooling type and able to be installed both indoor and outdoor.
CHARACTERISTIC
- Phase : 3Ø
- Frequency : 60Hz,50Hz
- Primary voltage : 22.9Kv
- Secondary voltage : 220, 380, 440, 208y/127, 380y/220, 400y/230, 440y/254
- TAP voltage : 23.9 – R22.9 – 21.9 – 20.9 – 19.9Kv
- Vector : Ddo, Dyn11. etc.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Capacity (kVA) Exciting Current (lo%) Voltage Regulation Efficiency (100%) Efficiency (50%) W (mm) D (mm) H (mm) 200 2.0 1.5 98.80 99.10 1270 820 1390 300 2.0 1.5 98.90 99.20 1320 870 1500 500 1.8 1.4 98.90 99.25 1370 950 1500 750 1.7 1.3 99.05 99.30 1420 1120 1550 1000 1.7 1.3 99.10 99.35 1570 1150 1730 2000 1.5 1.1 99.20 99.45 2030 1450 2200 2500 1.4 1.0 99.30 99.50 2520 1500 2460 3000 1.3 1.0 99.30 99.50 2550 1500 2500 -
Molded Transformer / Dry Type Transformer
PRODUCTS
APPLICATION
Molded transformer is high-efficient and low noise design product.
It used steel plate metal pin which applied grain refining treatment so that improve the energy loss.CHARACTERISTIC
- Phase : 3Ø
- Frequency : 60Hz,50Hz
- Primary voltage : 22.9Kv
- Secondary voltage : 220, 380, 440, 208y/127, 380y/220, 400y/230, 440y/254
- TAP voltage : 23.9 – R22.9 – 21.9 – 20.9 – 19.9Kv
- Vector : Ddo, Dyn11. etc.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Capacity (kVA) Exciting Current (lo%) Voltage Regulation Efficiency (100%) W (mm) D (mm) H (mm) 200 5.5 2.0 99.0 1235 790 1440 300 4.5 1.7 99.10 1330 795 1435 500 3.0 1.5 99.30 1375 840 1500 750 2.5 1.4 99.30 1445 840 1640 1000 2.5 1.3 99.40 1660 1020 1800 2000 2.0 1.1 99.50 2070 1150 2250 2500 2.0 1.1 99.50 2200 1250 2250 3000 2.0 1.0 99.50 2370 1250 2325 -
Power Transformer
PRODUCTS
APPLICATION
Power transformer adjusts high voltage from power plant to distribution line.
It is widely applied to high-power accepting system.CHARACTERISTIC
- hase : 3Ø
- Frequency : 60Hz,50Hz
- Primary voltage : 22.9Kv
- Secondary voltage : 6.6/3.3kV
- TAP voltage : 23.9 – R22.9 – 21.9 – 20.9 – 19.9Kv
- Vector : Ddo, Dyn11. etc.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Capacity (kVA) Exciting Current (lo%) Voltage Regulation Efficiency (100%) W (mm) D (mm) H (mm) 1000 4.5 1.3 98.4 2200 1950 1700 1500 4.5 1.25 98.5 2600 2100 2600 2000 4.5 1.2 98.5 2900 2200 2800 2500 4.0 1.2 98.7 3100 2500 2900 3000 4.0 1.2 98.7 3100 2600 3050 5000 4.0 1.21 98.9 3200 3000 3100 7500 3.5 1.0 99.1 3400 3400 3300 10000 3.5 1.0 99.2 3600 3800 4000 -
Hybrid / Polymer Bushing for Pole Transformer
PRODUCTS
APPLICATION
Protects high voltage and low voltage side terminal of pole transformer
CHARACTERISTIC
- Excellent impact resistance
- Prevent oil leakage
- High water repellency
- Light weight & Easy installation
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specifications Units High Low Rated current A 40 500 Material – Porcelain / Silicone Porcelain-FRP / Silicone Power frequency withstand voltage (dry) kV 42 15 Power frequency withstand voltage (wet) kV 36 15 Lightning impulse withstand voltage
(1.2 × 50μs)kV 125 – Leakage distance mm 770 ±40 – -
Bushing, Bushingwell for PAD Transformers
PRODUCTS
APPLICATION
Connects underground power cables and transformers.
CHARACTERISTIC
- Excellent tightening
- Excellent endurance and insulation
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specifications Units Bushing Bushing well Rated voltage V 400 25,800 Voltage(Max)
Phase-groundkV – 15.2 Voltage(Max)
Phase-phasekV – 26 Lightning impulse withstand voltage kV 30 125 Power frequency withstand voltage (1 min) kV 10 40 Direct current withstand voltage (15 min) kV – 78 Partial Discharge pC – 3
View Switchgears catalog
-
Cubicle Type Switchgear (Dry-Air & SF6 Gas insulated)
PRODUCTS
APPLICATION
Cubicle type switchgear is designed for stable power distribution in substations.
With its cubicle structure and highly reliable control system, it provides best solution for service
in private utility network such as substation in industrial and public buildings.CHARACTERISTIC
- Easy maintenance and reliable operation
- Digitally controlled system with protection features
- Ensured safety to operating person
- Requires minimum installation space
- Expandable modular system
- Three-phase enclosure of functional compartments
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Unit SF6 Gas Type Dry-Air Type Rated voltage kV 25.8 25.8 Rated short time withstand current (kA/1sec, RMS) 25 25 Rated current A Busbar: 2,000
Feeder: 630Busbar: 2,000
Feeder: 630Power frequency withstand voltage kV 70 60 Impulse withstand voltage kV 150 150 Rated interrupting current kA 25 25 Standard operation obligation – O-0.3sec-CO-15sec-CO O-0.3sec-CO-15sec-CO Protection degree – IP65 / IP4X IP65 / IP4X Mechanical endurance times 10,000 10,000 Applied Standard – IEC 62271-100,
KEPCO std.IEC 62271-100,
KEPCO std. -
SF6 Gas insulated Pad mounted Load Break Switch
PRODUCTS
APPLICATION
SF6 gas insulated pad mounted load break switch is designed to achieve optimum performance and reliability
with low maintenance cost and long lifespan.
It can be installed for underground distribution lines to perform current breaking and data gathering.CHARACTERISTIC
- Easy maintenance and reliable operation
- Light weight and easy installation
- Safety mechanism (low pressure interlocking, pressure relief and safety locks)
- Automation applied (Remote controllable with RTU and modem)
- Voltage measuring, status monitoring
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Unit Value Rated voltage kV 15 / 24 (25.8) / 35 (40.5) Rated current A 600 Rated short time withstand current kA, RMS 12.5 Rated short circuit making current kA, peak 32.5 Power frequency withstand voltage kV 50 / 60 / 95 Impulse withstand voltage kV 125 / 125 / 195 Rated load switching performance times 200 Mechanical endurance times 5,000 Weight (Automatic / Manual) kg 450 / 320 Applied Standard – IEC 62271-103, KEPCO std. -
SF6 Gas insulated Pole mounted Load Break Switch
PRODUCTS
APPLICATION
Pole mounted SF6-Gas insulated load break switch is designed to achieve optimum performance and reliability
with low maintenance cost and long lifespan.
The integrated type controller includes RTU (remote control, status monitoring), metering (current, voltage,
power factor, frequency, counter) & recording (events, fault current waveforms, data logging).CHARACTERISTIC
- Easy maintenance and reliable operation
- Compact design and easy installation
- Safety mechanism (low pressure interlocking, pressure relief and safety locks)
- Automation applied (Remote controllable with RTU and modem)
- Voltage measuring, status monitoring
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Unit Value Rated voltage kV 12 (max.15) / 24 (max.27) / 36 (max.38) Rated current A 400 / 630 / 800 Rated short time withstand current kA, RMS 12.5 / 16 / 20 Rated short circuit making current kA, peak 32.5 / 40.5 Power frequency withstand voltage kV 50 / 60 / 70 Impulse withstand voltage kV 125 / 150 / 170 Manual / Automatic – Manual / Automatic Mechanical endurance times 5,000 Weight kg 130, 145 Applied Standard – IEC 60265-1, IEC 62271-103, KEPCO std. -
Eco Load Break Switch
PRODUCTS
APPLICATION
ECO Load Break Switch is a eco-friendly product which is designed to use epoxy molded bushings.
The integrated type controller includes RTU (remote control, status monitoring), metering (current, voltage,
power factor, frequency, counter) & recording (events, fault current waveforms, data logging).CHARACTERISTIC
- maintenance and reliable operation
- Compact design and easy installation
- Automation applied (Remote controllable with RTU and modem)
- Voltage measuring, status monitoring
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Unit Value Rated voltage kV 12 (max. 15) / 24 (max. 27) Rated active load interrupting current A 400 / 630 Rated short-time current kA, RMS 12.5 Rated short circuit making current kA, peak 32.5 Rated power frequency withstand voltage kV 50 / 60 Impulse withstand voltage kV 125 / 150 Manual / Automatic – Manual / Automatic Mechanical endurance times 5,000 Weight kg 110 Applied Standard – IEC 62271-103, KEPCO std. -
SF6 Gas Insulated Sectionalizer
PRODUCTS
APPLICATION
SF6 gas insulated sectionalizer is designed for a self-contained circuit-opening device used in junction with
source-side protective devices such as reclosers and circuit breakers.
It automatically isolate faulted sections of electrical distribution systems.SF6 gas insulated sectionalizer is designed for a self-contained circuit-opening device used in junction with source-side protective devices such as reclosers and circuit breakers.
It automatically isolate faulted sections of electrical distribution systems.The sectionalizer has distinct application advantages
- It can be applied between two protective devices having operating curves, which are close together.
This is a vital feature in a location where an additional step in coordination is not practical or possible. - It can be used on close-in taps where fault current is highly frequent, coordinating with fuses.
- It has fault close and latch capability for any fault-closing operations.
CHARACTERISTIC
- Easy maintenance and reliable operation
- Compact design and easy installation
- Safety devices (low pressure interlocking, pressure relief, and safety locks)
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Unit Value Rated voltage kV 12 (max.15) / 24 (max.27) / 36 (max.38) Rated current A 400 / 630 Power frequency withstand voltage kV 50 / 60 / 70 Impulse withstand voltage kV 125 / 150 / 170 Rated short time withstand current kA, RMS 10 / 12.5 / 16 Rated short circuit making current kA, peak 26 / 32.5 / 40 Minimum running current A (Phase) 50, 70, 100, 140, 200, 300, 400A (Block) A (Ground) 25, 35, 50, 70, 100, 150, 200A (By Pass) Rated short circuit breaking current A 900 Applied Standard – IEEE Std 37.63 / IEC60265-1, KEPCO std. - It can be applied between two protective devices having operating curves, which are close together.
-
SF6 Gas Insulated Vacuum Recloser
PRODUCTS
APPLICATION
SF6 gas insulated vacuum recloser is designed to use on overhead distribution lines as well as distribution
substation applications.
The magnetic actuator provides highly efficient and reliable performance while consuming very little energy.
It has a microprocessor based controller that provides the protection, data logging and communication functions.SF6 gas insulated vacuum recloser is designed to use on overhead distribution lines as well as distribution substation applications.
The magnetic actuator provides highly efficient and reliable performance while consuming very little energy.
It has a microprocessor based controller that provides the protection, data logging and communication functions.CHARACTERISTIC
- Fault detection & protection.
- Self-diagnosis control & status monitoring
- Adjusting T-C curve
- Sequence operational test (trip, reclosing, resetting)
- Recording (events, fault current waveforms, data logging)
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Unit Value Rated voltage kV 12 (max.15) / 24 (max.27) / 36 (max.38) Rated current A 400 / 630 / 800 Rated short circuit making current kA, peak 32.5 / 40 Minimum running current A (Phase) 10–1600A (step: 1A) A (Ground) 2–1600A (step: 1A) Rated short circuit breaking current kA 12.5 / 16 Power frequency withstand voltage kV 50 / 60 / 70 Impulse withstand voltage kV 125 / 150 / 170 (200) Manual / Automatic – Magnetic Actuator Mechanical endurance times 5,000 / 10,000 Weight kg 160 / 160 / 300 Applied Standard – ANSI C37.60, IEC62271-111, KEPCO std. -
Pole Mounted Epoxy-Molded Vacuum Recloser
PRODUCTS
APPLICATION
Mold Epoxy-Molded recloser combines the high reliability of vacuum interruption and high dielectric strength
of encapsulated with cycloaliphatic epoxy resin.
The magnetic actuator provides consistent performance for automated distribution applications.
It has a microprocessor based controller that provides the protection, data gathering and communication function.CHARACTERISTIC
- Solid insulation (eco-friendly)
- Self-diagnosis control & status monitoring
- Permanently sealed enclosure with stainless steel
- Built-in integrated sensors
- Fast auto-reclosing capability
- Recording (events, fault current waveforms, data logging)
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Unit Value Rated voltage kV 12 (max.15) / 24 (max.27) / 36 (max.38) Rated current A 400 / 630 / 800 Power frequency withstand voltage kV 50 / 60 / 70 Impulse withstand voltage kV 125 / 150 / 70 Rated short circuit breaking current kA 12.5 / 16 Rated short circuit making current kA, peak 32.5 / 40 Minimum running current A (Phase) 10–1600A (step: 1A) A (Ground) 2–1600A (step: 1A) Manual / Automatic – Magnetic Actuator Mechanical endurance time 5,000 / 10,000 Weight kg 190 / 190 / 280 Applied Standard – ANSI C37.60, IEC 62271-111 -
Polymer Bushing for Switchgear
PRODUCTS
APPLICATION
Bushings are used to provide the essential insulation when a high voltage line passes through a metal sheet or
frame that is at ground potential. Primary Disconnect Bushings are the key components of the switchgear
that serve as the connection points to energize the network downstream of the switchgear.Bushings are used to provide the essential insulation when a high voltage line passes through a metal sheet or frame that is at ground potential.
Primary Disconnect Bushings are the key components of the switchgear that serve as the connection points to energize the network downstream of the switchgear.CHARACTERISTIC
- Switchgear and power apparatus installations
- Designed for extreme environmental conditions
- Cast in high dielectric strength grey silicone
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specifications Units 17.5 27 36 Rated voltage kV 17.5 27 36 Rated normal current A ≤630 Power frequency withstand voltage (Dry) kV 50 60 80 Power frequency withstand voltage (Wet) kV 38 50 70 Lightning impulse flashover voltage kV 125 150 180 Leakage distance mm 770 910 1320 Arcing distance mm 310 360 490 PD (1.5 Um /√3) pC ≤10 ≤10 ≤10 Flammability grade (UL 94) – V-0
View Other Distribution Products catalog
-
Composite Dead-end/Suspension Insulators
PRODUCTS
APPLICATION
Used in distribution lines and supports insulation of wires, having good electrical properties and high reliability
compared to porcelain insulator.Used in distribution lines and supports insulation of wires, having good electrical properties and high reliability compared to porcelain insulator.
CHARACTERISTIC
- Easy installation and light weight
- Excellent mechanical strength
- Excellent insulation in polluted environment
- High water repellency by using silicone
- Registered on KEPCO qualified supplier list
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Unit 36kV (A) 25kV (B) 15kV (C) Power frequency flashover voltage (Dry) kV 145 130 95 Power frequency flashover voltage (Wet) kV 130 110 70 Lightning impulse flashover voltage (1.2×50μs, Positive) kV 230 175 155 Lightning impulse flashover voltage (1.2×50μs, Negative) kV 253 212 175 Specified mechanical load (SML) kN 70 70 70 Section length mm 525±25 430±20 330±15 Leakage distance mm 760 580 425 Dry arcing distance mm 320 280 210 -
Composite Line post Insulators
PRODUCTS
APPLICATION
Line post insulators are designed to provide rigid support of conducting cable
while offering the maximum resistance to damage from electrical or mechanical eventsLine post insulators are designed to provide rigid support of conducting cable while offering the maximum resistance to damage from electrical or mechanical events
CHARACTERISTIC
- Excellent water repellency and ozone-proof
- Safety by excellent mechanical strength
- Easy installation and light weight
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Units Characteristics Power frequency withstand voltage (Dry) kV 110 Power frequency withstand voltage (Wet) kV 85 Lightning impulse flashover voltage (1.2×50μs, Positive) kV 166 Lightning impulse flashover voltage (1.2×50μs, Negative) kV 189 Specified cantilever load (SCL) kN 12 Specified mechanical load (SML) kN 12 Leakage distance mm 712 Dry arcing distance mm 264 -
Composite Coupling Insulator
PRODUCTS
APPLICATION
Coupling insulator is used to reinforce the insulation performance of COS or lightning arrestor
CHARACTERISTIC
- Light weight
- Excellent mechanical strength
- High water repellency
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Units Characteristics Pollution-withstand voltage (ESDD 3.5 g/m²) kV min 7 Power frequency withstand voltage (dry 1min) kV 42 Lightning impulse withstand voltage (1.2×50μs) kV 125 Specified mechanical load (for Bending) kN 9.8 Specified mechanical load (SML) kN 9.8 Leakage distance mm min 420 -
Composite Bus Support Insulator
PRODUCTS
APPLICATION
This insulator is mainly used for low voltage power distribution cabinets, frequency converters, and other products.
CHARACTERISTIC
- Light weight
- High water repellency
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Units PIH64₄ PIG20B₄ Item – PIH64₄ PIG20B₄ Nominal voltage / Rated voltage kV 6.6 / 7.2 22 / 24 Power frequency flashover voltage (Wet) kV 22 50 Lightning impulse flashover voltage kN 70 150 Leakage distance mm 770 1320 -
Elbow Connector (25kV, 200A Loadbreak)
PRODUCTS
APPLICATION
Connects 25kV underground distribution line cables and transformers
CHARACTERISTIC
- Applicable to both cable types (Cu / Al)
- Designed for electric field distribution
- Excellent shielding function
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specifications Units Characteristics Rated voltage kV 25.8 Maximum voltage – Phase-Ground kV 15.2 Maximum voltage – Phase-Phase kV 26 Lightning impulse withstand voltage (1.2×50μs) kV 125 Power frequency withstand voltage (1min) kV 40 Direct current withstand voltage (15 min) kV 78 Short time withstand current – 0.17 seconds A 10,000 Short time withstand current – 3 seconds A 3,500 Partial discharge pC Max. 3 -
Elbow Connector (25kV, 600A Deadbreak)
PRODUCTS
APPLICATION
Connects 25kV underground distribution line cables and switches
CHARACTERISTIC
- Applicable to both cable types (Cu / Al)
- Designed for electric field distribution
- Excellent shielding function
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specifications Units Characteristics Rated voltage kV 25.8 Maximum voltage Phase-ground (kV) 15.2 Phase-phase (kV) 26.3 Lightning impulse withstand voltage (1.2×50μs) kV 125 Power frequency withstand voltage (1 min) kV 40 Direct current withstand voltage (15 min) kV 78 Short time withstand current 0.17 seconds (A) 25,000 3 seconds (A) 10,000 Partial discharge pC Max. 3 -
23kV Class Cable Termination
PRODUCTS
APPLICATION
Used for terminal connection processing of power cable end of 23kV underground distribution line
CHARACTERISTIC
- Designed for electric field distribution
- Excellent shielding function
- Cast in high dielectric strength grey silicone
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Units Characteristics Rated voltage kV 23 Lightning impulse withstand voltage (1.2×50μs) kV 150 Power frequency withstand voltage (1 min) kV 65 Direct current withstand voltage (15 min) kV 100 Partial discharge pC Max. 3 -
23kV Class Cable Joint
PRODUCTS
APPLICATION
Used for terminal connection processing of power cable end of 23kV underground distribution line.
CHARACTERISTIC
- Designed for electric field distribution
- Excellent shielding function
- Cast in high dielectric strength grey silicone
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Units Characteristics Rated voltage kV 23 Lightning impulse withstand voltage (1.2×50μs) kV 150 Power frequency withstand voltage (1 min) kV 52 Direct current withstand voltage (15 min) kV 100 Partial discharge pC Max. 3 -
Polymer Cut out Switch (125BIL, 150BIL)
PRODUCTS
APPLICATION
Protects equipment from overcurrent due to short circuit or ground accidents or overload.
CHARACTERISTIC
- Excellent insulation and mechanical properties
- Excellent water repellency
- Ligiht weight and easy installation
- 125BIL, 150 BIL 2-Types
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specifications Units Characteristic Value Characteristic Value Rated voltage kV 25.8 25.8 Maximum design voltage kV 27 27 Rated current A 100 100 Rated breaking current kA Sym 7.1
Asym 10Sym 8
Asym 12Power frequency withstand voltage (Dry) kV 42 70 Power frequency withstand voltage (Wet) kV 36 60 Lightning impulse withstand voltage (1.2×50μs) kV 125 150 Leakage distance mm 400 645 -
Polymer Surge Arrester
PRODUCTS
APPLICATION
Protects the rear end facilities in case of lightning and abnormal voltage intrusion into the processing power line.
It also limits overvoltage by switching circuits and is used to block the flowCHARACTERISTIC
- Moisture-proof by direct molded unit
- Optimal structure and high durability
- Applicated zinc oxide block to ensure safety
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Unit Characteristics Rated voltage kV 18 Max. continuous operating voltage (MCOV) kV 15.3 Nominal discharge current A 2,500 / 5,000 Reference voltage kV min 22.9 Residual voltage – Steep voltage kV 66 Residual voltage – Lightning impulse voltage kV 60 Partial discharge pC Max. 10 Leakage distance mm min 645 -
Polymer Surge Arrester with Lead wire
PRODUCTS
APPLICATION
Protects the rear end facilities in case of lightning and abnormal voltage intrusion into the processing power line.
Also limits overvoltage by switching circuits and is used to block the flow.
This product has a lead wire connected to a polymer lightning arrestor.CHARACTERISTIC
- Moisture-proof by direct molded unit
- Optimal structure and high durability
- Applicated zinc oxide block to ensure safety
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Unit Characteristics Rated voltage kV 18 Max. continuous operating voltage (MCOV) kV 15.3 Nominal discharge current A 2,500 / 5,000 Reference voltage kV min 22.9 Residual voltage – Steep voltage kV 66 Residual voltage – Lightning impulse voltage kV 60 Partial discharge pC Max. 10 Leakage distance mm min 645 -
Polymer Arrester (Gap Type)
PRODUCTS
APPLICATION
Gap type arrester protects LP insulators and other applications from lightning and surge.
CHARACTERISTIC
- Moisture-proof by direct molded unit
- Optimal structure and high durability
- Light weight and miniaturized design
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specifications Units Characteristics Rated voltage kV 18 Nominal discharge current kA 2.5 Residual voltage kV max. 55 Power frequency withstand voltage (Dry) kV 42 (1 min) Power frequency withstand voltage (Wet) kV 36 (10 seconds) Lightning impulse flashover voltage (Pos) kV 95–150 Lightning impulse flashover voltage (Neg) kV 105–160 Partial discharge pC Max. 10
View Insulators for Railways catalog
-
Composite Suspension Insulator for Railways (T-s)
PRODUCTS
APPLICATION
It is used for classifying 69kV transmission line and railway line, suspention feeder lines,
and has excellent insulation and mechanical properties.CHARACTERISTIC
- Excellent mechanical characteristics and insulation
- High water repellency by using silicon
- Easy installation by light weight
- Excellent insulation in contaminated environment
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Unit Characteristics
No.1Characteristics
No.2 & 3Section length mm 750 ±5 760 ±5 Leakage distance mm min 1,725 min 1,725 Dry arcing distance mm min 570 min 570 Specified mechanical load (SML) kN 137.2 137.2 Rated tensile load (RTL) kN 68.6 68.6 Torsion load (1 min) N·m 50 50 Power frequency withstand voltage (dry) kV 230 230 Power frequency withstand voltage (wet) kV 185 185 Lightning impulse flashover voltage (1.2×50μs, Positive) kV 380 380 Lightning impulse flashover voltage (1.2×50μs, Negative) kV 380 380 -
Composite Suspension Insulator for High-speed Railways (T-sx)
PRODUCTS
APPLICATION
It is used to distinguish 25kV high-speed railway tram lines and to suspend feeder lines,
and has excellent insulation and mechanical properties.CHARACTERISTIC
- Excellent insulation and mechanical properties
- High water repellency of polymer material
- Convenient construction with light weight
- Excellent insulation performance in contaminated environment
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specifications Units Characteristics Leakage distance mm min 1,300 Specified mechanical load (SML) kN 110 Rated tensile load (RTL) kN 55 (10 second) Power-frequency withstand voltage (wet) kV 95 Lightning impulse withstand voltage (1.2×50μs) kV 250 Radio interference voltage kV 27.5 Radio interference voltage μV at 1000kHz 10 -
Insulators for Railway / T-m / T-ms
PRODUCTS
APPLICATION
Used for operating bracket of 25kV high-speed rail tracks and has excellent insulation and mechanical features
CHARACTERISTIC
- Composite insulator using for 25kV railway tensioning position
- Excellent insulation and mechanical properties
- High water repellency
- Light weight & easy installation
- Excellent insulation performance in contaminated environment
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION / T-m
Specifications Unit Characteristics Leakage distance mm A-B: min 1,250 / C-D: min 230 Specified cantilever load (SCL) N·m min 3,430 Rated tensile load (RTL, 1 min) N 58,800 Power frequency flashover voltage (dry) kV A-B: min 230 / C-D: min 70 Power frequency flashover voltage (wet) kV A-B: min 180 / C-D: min 50 Lightning impulse flashover voltage (1.2×50μs) kV A-B: min 380 / C-D: min 100 Radio Interference Voltage r.m.s kV 25 Radio Interference Voltage μV at 1000kHz 10 SPECIFICATION / T-ms
Specifications Unit Characteristics Leakage distance mm min 1,250 Specified cantilever load (SCL) N·m min 3,430 Rated tensile load (RTL, 1 min) N 58,800 Power frequency flashover voltage (dry) kV min 230 Power frequency flashover voltage (wet) kV min 180 Lightning impulse flashover voltage (1.2×50μs) kV min 380 Radio interference voltage r.m.s kV 25 Radio interference voltage μV at 1000kHz 10 -
Composite Long Rod Insulator for High-speed Railways (T-mx)
PRODUCTS
APPLICATION
Composite insulator applied to 25kV High-speed railway (T-mx).
CHARACTERISTIC
- Excellent insulating and mechanical properties
- High water repellency
- Light weight and easy installation
- Excellent insulation performance in contaminated environment
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specification Units Characteristics Leakage distance mm min 1,300 Specified cantilever load (SCL) N·m min 4,000 Specified mechanical load (SML) kN 90 Rated tensile load (RTL) kN 45 (for ten seconds) Power-frequency withstand voltage (wet) kV 95 Lightning impulse withstand voltage (1.2×50μs) kV 250 Radio Interference Voltage kV 27.5 Radio Interference Voltage μV at 1000kHz 10 -
Composite Tension Insulator for Railways (N-a)
PRODUCTS
APPLICATION
It is used for Dead-and line and division point of 25kV tram lines,
and has excellent insulation and mechanical properties.It is used for Dead-and line and division point of 25kV tram lines, and has excellent insulation and mechanical properties.
CHARACTERISTIC
- Composite insulator using for 25kV railway tensioning position
- Excellent insulation and mechanical properties
- High water repellency
- Excellent insulation performance in contaminated environment
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specifications Unit Rating Leakage distance mm A·B: min 1,400 / C·D: min 240 Specified cantilever load (SCL) N min 1,863 Rated tensile load (RTL, 1 min) N 54,917 Power frequency flashover voltage (dry) kV A·B: min 250 / C·D: min 80 Power frequency flashover voltage (wet) kV A·B: min 200 / C·D: min 55 Lightning impulse withstand voltage (1.2×50μs) kV A·B: min 400 / C·D: min 110 -
Insulators for Railway / NSP-40
PRODUCTS
APPLICATION
Insulators used to support AT feeders and conductors in underground sections, tunnels,
and bridges of railroad tracks (general and high-speed railways)CHARACTERISTIC
- High water repellency
- Excellent insulating and mechanical properties
- Light weight and convenient construction by applying aluminum fitting
- Excellent insulation performance in contaminated environment
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specifications Units Characteristics Leakage distance mm min 1,300 Specified cantilever load (SCL) N min 5,000 Rated tensile load (RTL) kN 40 Specified Mechanical Load (SML) kN 80 Power-frequency flashover voltage (wet) kV 95 Lightning impulse withstand voltage (1.2×50μs) kV 250 Radio interference voltage r.m.s kV 27.5 Radio interference voltage μV at 1000kHz 10 -
Insulators for Railway / NSP-50
PRODUCTS
APPLICATION
Insulators used to support AT feeders and conductors in underground sections, tunnels,
and bridges of railroad tracks (general and high-speed railways)CHARACTERISTIC
- High water repellency
- Excellent insulating and mechanical properties
- Light weight and convenient construction by applying aluminum fitting
- Excellent insulation performance in contaminated environment
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to fit customer’s requirements.
Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.SPECIFICATION
Specifications Units Characteristics Leakage distance mm min 1,100 Specified cantilever load (SCL) N min 6,963 Rated tensile load (RTL) N 39,227 Power-frequency flashover voltage (dry) kV 200 Power-frequency flashover voltage (wet) kV 150 Lightning impulse withstand voltage (1.2×50μs) kV min 320 Radio interference voltage r.m.s kV 25 Radio interference voltage μV at 1000kHz 10