Composite Tension Insulator for Railways (N-a)

Back to All Products

PRODUCTS

APPLICATION

It is used for Dead-and line and division point of 25kV tram lines,
and has excellent insulation and mechanical properties.

It is used for Dead-and line and division point of 25kV tram lines, and has excellent insulation and mechanical properties.

CHARACTERISTIC

  • Composite insulator using for 25kV railway tensioning position
  • Excellent insulation and mechanical properties
  • High water repellency
  • Excellent insulation performance in contaminated environment

Specifications shown below can be adjusted, without notice, to improve its performance.

The product can be customized to fit customer’s requirements.

Specifications shown below can be adjusted, without notice, to improve its performance.
The product can be customized to
fit customer’s requirements.

SPECIFICATION

SpecificationsUnitRating
Leakage distancemmA·B: min 1,400 / C·D: min 240
Specified cantilever load (SCL)Nmin 1,863
Rated tensile load (RTL, 1 min)N54,917
Power frequency flashover voltage (dry)kVA·B: min 250 / C·D: min 80
Power frequency flashover voltage (wet)kVA·B: min 200 / C·D: min 55
Lightning impulse withstand voltage (1.2×50μs)kVA·B: min 400 / C·D: min 110